- Contact Person : Mr. wei ren
- Company Name : Chongqing Head Automatization Co., Ltd.
- Tel : 0086-023-63176116
- Fax : 0086-023-68241313
- Address : Chongqing,Chongqing,11 Floor Hai Yu Building No.9, ShuangYuna Road, BeiBei District
- Country/Region : China
- Zip : 400700
EJA115 YOKOGAWA Low Flow Transmitter
We supply the following YOKOGAVA Transmitter:
1> EJA110A
2> EJA120A
3> EJA130A
4> EJA210A/220A
5> EJA310A
6> EJA430A.
7> EJA440A
8> EJA510A/EJA530A
9> EJA118
10> EJA438
11> EJA115
12> EJA213
PRODUCT INFORMATION:
The model EJA115 Low Flow Transmitter is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4 to 20 mA DC signal corresponding to the measured flow. The orifice is available in six types with a bore ranging from 0.508 mm to 6.350 mm. The combination of the bore selection with the differential pressure measurement span variation of the differential pressure transmitter enables a wide range of very small flow measurement.
The EJA Series is available with BRAIN, HART, FOUNDATION fieldbus or PROFIBUS PA communication protocols.
FEATURES:
--Excellent performance and stability
The EJA series uses a formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
-- Compact and light-weight design
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
-- Fieldbus communication capability
Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.EJA series offers two types of fieldbus models, FOUNDATION fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation
PARAMETERS:
EJA115 Low Flow Transmitter | ||||
L Capsule | M Capsule | H Capsule | ||
Water equivalent | 0.016 to 7.2 l/min | 0.022 to 23 l/min | 0.07 to 33 l/min | |
Air equivalent flow | 0.44 to 198 Nl/min | 0.63 to 635 Nl/min | 2 to 910 Nl/min | |
Differential pressure span | 1 to 10 kPa(2 to 40 inH2O) | 2 to 100 kPa(8 to 400 inH2O) | 20 to 210 kPa(80 to 840 inH2O) | |
Accuracy | ±5% | ±5% | ±5% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | |||
Certificates | FM, CENELEC ATEX, CSA, TIIS, IECEx | |||
Output | 4 to 20 mA DC or FOUNDATION fieldbus or PROFIBUS PA 2-wire system with digital communication | |||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model) | |||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type)-30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | |||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | |||
Maximum working pressure | 3.5 MPa(500 psi) | 14 MPa(2000 psi) | ||
Mounting | 2-inch pipe mounting | |||
Wetted parts material | Capsule | SUS316L(Diaphragm material is Hastelloy C-276) | ||
Manifold | SUS316 | |||
Cover flange | SUS316 | |||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |
EJA115 YOKOGAWA Low Flow Transmitter